PRODUCTS

SRL type finned tube radiator

Quality first, attentive service

The SRL finned tube radiator can effectively dissipate heat during use, which relies on the coordination between its components.
1. Running wind: Running wind is an important component of the radiator, mainly used to release air from the radiator. During the heating period, there will always be gas generated in the heating system. If it is not discharged, it will block the normal operation of hot water and affect the heat dissipation of the entire heating system.
2. Screw plug: Screw plugs are generally used at the end of radiators to provide a sealing effect, allowing hot water to flow inside without problems such as water leakage.

SRL type finned tube radiator

Product overview

The SRL finned tube radiator can effectively dissipate heat during use, which relies on the mutual cooperation between accessories. Below are the specific accessories required for the installation of finned tube radiators.
1. Running wind: Running wind is an important component of the radiator, mainly used to release air from the radiator. During the heating period, there will always be gas generated in the heating system. If it is not discharged, it will block the normal operation of hot water and affect the heat dissipation of the entire heating system.
2. Screw plug: Screw plugs are generally used at the end of radiators to provide a sealing effect, allowing hot water to flow inside without problems such as water leakage. Structurally speaking, screw plugs are commonly used accessories in plumbing systems, which bear significant system pressure and are susceptible to corrosion. Under the physical effects of thermal expansion and contraction, they can withstand tests such as freezing, cracking, expansion, and water leakage.
3. Expansion nail and hook: These two types of radiator accessories are used to fix the radiator on the wall. There are significant differences between current products and traditional radiators. Generally, users will hang them directly on the wall without the need for additional heating covers. Expansion pins can prevent the radiator from shaking or shifting.
The mutual coordination between accessories is important for SRL finned tube heat sinks, which can maintain normal and stable operation while playing a good role in heat dissipation.
 

The heat transfer coefficient and resistance of SRL finned tube radiator are shown in the following table

Heat sink model Thermal medium Heat transfer coefficient K value
Kilocalories per square meter at 2 ℃
Resistance millimeter water column
SRLB×A/2 Steam (one gauge pressure) K=13.1(Vγ)0.40 H=0.174(Vγ)1.67
Hot water at 130 ℃
(Flow rate 0.023-0.037)
K=14.2(Vγ)0.24 H=0.153(Vγ)1.58
SRLB×A/3 Steam (one gauge pressure) K=13.0(Vγ)0.43 H=0.309(Vγ)1.62
Hot water at 130 ℃
(Flow rate 0.0154-0.038)
K=12.5(Vγ)0.29 H=0.296(Vγ)1.58

Technical parameter

Heat sink model Ventilation net cross-sectional area
(m²)
Heat dissipation area
(m²)
Heat medium Number of bundles Heating area
(m²)
Heat medium passing through cross-sectional area
(m²)
Size (mm) Coupling tube Weight
(kg)
A B A1 B1 A2 B2 A3 B3 C
SRL-5×5/3 0.11 16.7   35 0.88 0.0070 500 400 545 500 575 540 605 570 200 5"/4 51
SRL-5×5/2 0.11 11.0 23 0.58 0.0046 160 38
SRL-10×5/3 0.22 34.0 35 1.76 0.0070 900 1000 1040 1070 200 83
SRL-10×5/2 0.22 22.3 23 1.16 0.0046 160 50
SRL-12×5/3 0.27 42.6 35 2.20 0.0070 1200 1250 1290 1320 200 99
SRL-12×5/2 0.27 28.0 23 1.45 0.0046 160 71
SRL-6×6/3 0.15 23.6 41 1.24 0.0082 600 500 635 600 665 640 695 670 200 3"/2 66
SRL-6×6/2 0.15 15.6 27 0.82 0.0054 160 43
SRL-10×6/3 0.26 39.8 41 2.06 0.0082 900 1000 1040 1070 200 95
SRL-10×6/2 0.26 26.2 27 1.36 0.0054 160 59
SRL-12×6/3 0.32 49.9 41 2.58 0.0082 1200 1250 1290 1320 200 113
SRL-12×6/2 0.32 32.9 27 1.70 0.0054 160 81
SRL-15×6/3 0.39 60.0 41 3.09 0.0082 1400 1500 1540 1570 200 131
SRL-15×6/2 0.39 39.5 27 2.04 0.0054 160 94
SRL-24×6/3 0.60 95.8 41 4.89 0.0082 2300 2400 2440 2470 200 197
SRL-24×6/2 0.60 63.1 27 3.23 0.0054 160 138
SRL-7×7/3 0.21 31.7 47 1.65 0.0094 700 600 725 700 755 740 785 770 200 2" 83
SRL-7×7/2 0.21 20.9 31 1.09 0.0062 160 60
SRL-10×7/3 0.30 45.7 47 2.36 0.0094 900 1000 1040 1070 200 107
SRL-10×7/2 0.30 31.0 31 1.56 0.0062 160 77
SRL-12×7/3 0.37 57.2 47 2.96 0.0094 1200 1250 1290 1320 200 127
SRL-12×7/2 0.37 37.8 31 1.95 0.0062 160 91
SRL-14×7/3 0.43 66.1 47 3.41 0.0094 1400 1450 1490 1250 200 144
SRL-14×7/2 0.43 43.6 31 2.25 0.0062 160 102
SRL-15×7/3 0.45 68.8 47 3.54 0.0094 1400 1500 1540 1570 200 148
SRL-15×7/2 0.45 45.4 31 2.34 0.0062 160 105
SRL-17×7/3 0.50 80.4 47 4.13 0.0094 1700 1750 1790 1820 200 169
SRL-17×7/2 0.50 53.1 31 2.73 0.0062 160 120
SRL-22×7/3 0.66 101.3 47 5.21 0.0094 2100 2200 2240 2270 200 196
SRL-22×7/2 0.66 66.8 31 3.43 0.0062 160 145
SRL-15×10/3 0.69 95.2 65 4.91 0.0130 1000 1400 995 1500 1025 1540 1055 1570 200 5"/2 215
SRL-15×10/2 0.69 63.0 43 3.25 0.0086 160 140
SRL-17×10/3 0.74 111.4 65 5.72 0.0130 1700 1750 1790 1320 200 226
SRL-17×10/2 0.74 73.6 43 3.89 0.0086 160 159
SRL-20×10/3 0.85 127.5 65 6.54 0.0130 1900 2000 2040 2070 200 252
SRL-20×10/2 0.85 84.2 43 4.33 0.0086 160 177
SRL-14×8/2 0.54 50.7 35 2.55 0.0070 800 1400 815 1450 845 1490 875 1520 160 2" 108